Regulatory KeratinoSens™ Skin sensitisation test

KERATINOSENS (OECD TEST GUIDELINE 442D)

WHY CONDUCT A KERATINOSENS™ SKIN SENSITISATION TEST?

Of the three human skin sensitisation tests that reflect Key Events in the Adverse Outcome Pathway (AOP), the KeratinoSens™ test represents Key Event 2, the activation of skin cells (keratinocytes) in the epidermis. Test items are classified based on a “two out of three” approach.

OVERVIEW

Skin sensitisation is defined as an allergic response following skin contact with the tested chemical, as defined by the United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS).

The test described here is fully accepted at a regulatory level for the hazard identification of Skin Sensitisers and Non-Sensitisers in accordance with the UN GHS. It is appropriate for compliance with a range of legislation including the EU Cosmetics Regulation 1223/2009 and the CLP Regulation 1272/2008. It was incorporated into REACH (Registration, Evaluation, Authorisation and restriction of CHemicals) legislation in 2016. Data generated using the KeratinoSens™ method should be considered in the context of an integrated approach i.e. in combination with other in vitro and in chemico skin sensitisation models.

The adverse outcome pathway leading to skin sensitisation involves a number of Key Events. This test method addresses Key Event 2, which takes place in the cells of the epidermis (keratinocytes). It induces inflammatory responses as well as gene expression associated with specific cell signalling pathways. The KeratinoSens™ cell line is a human keratinocyte cell line, containing a luciferase gene that is linked with a gene known to be up-regulated by contact sensitisers.

In this test, a sensitising test item switches on the luciferase-linked gene, meaning that luciferase itself is also produced by the cells. Quantitative measurement (by luminescence detection) of luciferase activity is then carried out using a standard substrate. The prediction model correlates the luciferase signal with sensitisation potential. A test item inducing luciferase activity by more than or equal to 1.5- fold over the untreated control level is classified as Positive (Sensitiser). A test item causing less than 1.5-fold induction is classified as Negative (Non-Sensitiser).

The standard KeratinoSens™ test includes the use of animal-derived components in the test system, such as bovine serum in the cell culture medium. In order to provide our clients with a truly animal-free test, XCellR8 has adapted the test to animal-product-free conditions, and validated the adapted method using the OECD listed proficiency chemicals and Performance Standards. This work has been published in peer-reviewed literature. In 2016, the European Chemicals Agency (ECHA) confirmed that the adapted method can be used in REACH registration dossiers, and the protocol has since been published in the new edition of OECD Test Guideline 442D (adopted June 2018).

TEST SYSTEM: KERATINOSENS™ CELL LINE

The KeratinoSens™ cell line was created from an immortalized human keratinocyte line called HaCaT. The cells were transfected with a plasmid containing the luciferase gene under the transcriptional control of an Antioxidant Response Element (ARE) from a gene that is known to be up-regulated by contact sensitisers. Luciferases are a group of oxidating enzymes that convert marker substrates into light-emitting products that can be quantified by luminescence. The luciferase activity signal measured in the test reflects the activation by sensitisers of endogenous Nrf2 dependent genes in the presence of sensitising test items. KeratinoSens™ cells must be maintained under strictly controlled culture conditions to maintain expression of the luciferase gene.

SUMMARY OF THE TEST METHOD

  • KeratinoSens™ cells are seeded into 96-well plates and cultured at 37°C / 5% CO2 for 24 hours.
  • On the day of testing, test items are prepared as stock solutions in DMSO and serially diluted in culture medium to give 12 test concentrations ranging from 0.098mM to 200mM. The final concentration of DMSO in the test plate wells is 1%.
  • The negative control is 1% DMSO and the positive control is cinnamic aldehyde.
  • For each test item, 3 independent runs of the test are performed, each consisting of 3 replicate plates. Therefore the total number of data points used for statistical analysis is 9.
  • The dosed plates are incubated at 37°C / 5% CO2 for 48 hours.
  • At the end of the exposure period, the plates are washed with phosphate buffered saline, prior to the addition of lysis buffer to each well for 20 minutes at room temperature.
  • Plates are then placed into a validated luminometer, which is programmed to add the luciferase substrate (50μl), wait for 1 second, then integrate luciferase activity for 2 seconds.
  • A cytotoxicity test (the MTT method) is performed in parallel plates, ensuring that the prediction of sensitisation potential is made using healthy, viable cells.
  • Data is analysed to provide the following parameters:
  • The EC1.5 value is the lowest concentration of test item that causes a luciferase induction greater than 1.5-fold above the negative control. If any of the test concentrations exceed or equal the 1.5 threshold, the test item is classified as Positive (Sensitiser). If no test concentrations exceed the 1.5 threshold, the test item is classified as Negative (Non- Sensitiser).
  • The IMAX value is the maximum induction achieved at any of the test concentrations. For example, an IMAX value of 3 means that the maximum-fold induction observed at any test concentration was 3. Although the KeratinoSens™ test is not validated to predict potency, the IMAX value can provide a useful tool for a very preliminary comparison of sensitisation potential between test items. For reference, during test validation, sensitising Proficiency Chemicals produced IMAX values of up to 26.
  • A range of acceptance criteria must be satisfied in order for each of the 3 independent experimental runs, and the overall test, to be considered valid.

Get in touch today to ask for pricing information.

Skin sensitisation test

At a glance

What it measuresActivation of keratinocytes
ComplianceOECD TG 442D
Turnaround time6-8 weeks
MethodKeratinoSens™
Sample required10ml (liquids) / 10g (solids)
Test codeCT-038

Always animal and animal product-free

 

Request A Quote

Test Required

Quantity of Test item

This form collects your data so that we can respond to your enquiry.

I consent to XCellR8 handling my data.

Please see our privacy policy for more information on how we protect and manage your data.

We’d like to send you occasional news from XCellR8 via email such as new product launches, regulatory updates and useful guides. We will never sell your data to anyone else and you can unsubscribe at any time.

Yes, I’d like to hear about news and services

No, I don’t want to hear about news and services

Enter the Captcha


Reload


Keep this information for your files